Test biologico per il monitoraggio dell'effetto antietà del trattamento del sangue del cordone ombelicale

Feb 27, 2022

Contatto:jerry.he@wecistanche.com


Sang-Hun Bae1*, Ala Jo1,2*, Jae Hyun Park1, Chul-Woo Lim1, Yuri Choi1, Juhyun Oh2, Ji-Min Park1, TaeHo Kong1, Ralph Weissleder2,3, Hakho Lee2, Jisook Moon1

1. Dipartimento di Biotecnologie, College of Life Science, CHA University, Gyeonggi-do 13488, Repubblica di Corea

2. Center for Systems Biology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA

3. Department of Systems Biology, Harvard Medical School, Boston, MA 02115, USA *Questi autori hanno contribuito allo stesso modo.

Autore corrispondente: Hakho Lee, PhD. Center for Systems Biology, Massachusetts General Hospital, 185 Cambridge St, CPZN 5206, Boston, MA 02114, USA. 617-726-8226 hlee@mgh.harvard.edu Jisook Moon, PhD. Dipartimento di Biotecnologie, College of Life Science, CHA University, Pangyo-ro 335, Bundang-gu, Seongnam-si, Gyeonggi-do 13488, Repubblica di Corea. 82-31-881-7210 jmoon@cha.ac.kr

© Ivyspring Editore Internazionale. Questo è un articolo ad accesso aperto distribuito secondo i termini della licenza Creative Commons Attribution (CC BY-NC) (https://creativecommons.org/licenses/by-nc/4.0/). Vedere http://ivyspring.com/terms per i termini e le condizioni completi.

Ricevuto: 04.10.2018; Accettato: 18. 11. 2018; Pubblicato: 01.01.2019

cistanche -whitening effect16

Cistanche ha un effetto antietà

Astratto

Sfondo: Il trattamento di animali anziani con plasma in una fase iniziale dello sviluppo (ad es. plasma del cordone ombelicale) ha mostrato un potenziale impressionante per rallentare il degrado delle funzioni neuronali e cognitive associato all'età. La traduzione di tali risultati in realtà cliniche, tuttavia, richiede metodi efficaci per valutare l'efficacia del trattamento; i metodi ideali dovrebbero essere minimamente invasivi, suscettibili di analisi seriali, convenienti e quantitativi.

Metodi: Abbiamo sviluppato un nuovo approccio di biosensore per il monitoraggioanti etàterapia. Abbiamo avanzato due componenti chiave del sensore: i) un metabolita ematico è stato identificato come marker di invecchiamento surrogato; e ii) è stato sviluppato un sistema di analisi compatto ed economico per applicazioni in loco. Abbiamo trattato topi invecchiati con plasma del cordone ombelicale umano o soluzione fisiologica; il profilo imparziale dei metaboliti sul plasma del topo ha rivelato che l'acido arachidonico (AA) è un potente indicatore associato alanti etàeffetto. Successivamente abbiamo implementato un sensore magnetoelettrochimico (cMES) competitivo ottimizzato per il rilevamento di AA direttamente dal plasma. La piattaforma sviluppata potrebbe rilevare AA direttamente da piccoli volumi di plasma (0,5 µL) entro 1,5 ore.

Risultati: i test cMES hanno confermato una forte correlazione tra i livelli di AA eeffetto antietà: i livelli di AA, mentre diminuivano con l'invecchiamento, sono aumentati nei topi anziani trattati con plasma che hanno anche mostrato un miglioramento delle prestazioni di apprendimento e memoria.

Conclusioni: la piattaforma cMES consentirà sia pre-che clinicaanti etàricerca consentendo la sorveglianza longitudinale e minimamente invasiva del trattamento; queste capacità accelereranno lo sviluppo dianti etàterapie, migliorando la qualità della vita delle persone.

Parole chiave: Antietà, Acido arachidonico, Profilazione dei metaboliti, Sensore magneto-elettrochimico, Biosensore

introduzione

L'invecchiamento è sempre più riconosciuto come un fattore di rischio clinico per la degenerazione cognitiva (p. es., neurodegenerazione, demenza) e altre malattie croniche (p. es., cancro, malattie cardiovascolari, degenerazione muscolare) [1]. Con l'espansione della durata della vita umana e l'aumento della popolazione anziana, sono in corso sforzi significativi per chiarire i meccanismi dell'invecchiamento [1-3] e per trovare strategie terapeutiche per rallentare o addirittura invertire i processi di invecchiamento [4]. In effetti, sono stati riportati risultati promettenti da studi sugli animali; topi adulti che hanno ricevuto una trasfusione di plasma da topi giovani hanno riacquistato la funzione cognitiva, la plasticità sinaptica e l'attività neuronale [5]. Rapido sviluppo inanti etàsono previsti trattamenti e la loro traduzione in sperimentazioni umane [6]. Le attuali metriche per monitorare gli effetti del trattamento, tuttavia, hanno una praticità limitata, poiché i metodi sono spesso difficili da applicare con gli esseri umani (p. es., imaging cerebrale invasivo, osservazione del comportamento controllata) e soggettivi (p. es., questionari sulle esperienze dei pazienti). Un requisito fondamentale per avanzareanti etàterapie risiede quindi nello sviluppo di saggi quantitativi e minimamente invasivi per il monitoraggio del trattamento.

Abbiamo pensato che i metaboliti sarebbero stati una potente fonte peranti etàbiomarcatori. I metaboliti sono un fenotipo essenziale in un organismo e vengono studiati come biomarcatori diagnostici per altre malattie [7]. In particolare, l'invecchiamento è tipicamente associato a cambiamenti o disfunzioni metaboliche, che influenzano i profili metabolici complessivi negli organismi. In quanto tale, è concepibile che tracciare la composizione e/o i livelli dei metaboliti ne informi l'efficaciaanti etàtrattamento. Inoltre, le analisi dei metaboliti, in particolare sotto forma di analisi del sangue, potrebbero essere quantitative e minimamente invasive; questi meriti faciliterebbero l'apprendimento di diversi regimi di trattamento o gruppi di pazienti e il monitoraggio delle dinamiche (anti-)invecchiamento attraverso un campionamento seriale.

Descriviamo qui una nuova strategia di biosensore per il monitoraggioanti etàtrattamento. Sono stati avanzati due elementi chiave: i) un metabolita ematico è stato identificato come marcatore dell'invecchiamento surrogato; e ii) è stato sviluppato un sistema di analisi rapido ed economico per applicazioni in contesti clinici di routine. In particolare, abbiamo trattato una coorte di topi anziani (di circa 2 anni) con plasma di sangue del cordone ombelicale umano. Analisi metabolomiche complete sul sangue di topo hanno rivelato che l'acido arachidonico (AA), il cui livello è diminuito significativamente con l'invecchiamento, è aumentato in modo inverso nel gruppo trattato. Questa osservazione ci ha portato a ideare un sensore magnetoelettrochimico per piccoli bersagli molecolari: abbiamo ottimizzato una reazione elettrochimica competitiva in cui l'AA veniva catturato su sfere magnetiche e concentrato per una maggiore sensibilità. La piattaforma sviluppata potrebbe rilevare AA direttamente da piccoli volumi di plasma (0,5 µL) entro 1,5 ore. Utilizzando questa piattaforma, potremmo stabilire ulteriormente una correlazione positiva tra i livelli di AA nel sangue e le migliori prestazioni degli animali nel compito motorio.

Risultati

Trattamento di topi adulti con plasma del sangue del cordone ombelicale La Figura 1a mostra lo schema generale dell'esperimento.

Come agente, abbiamo utilizzato plasma derivato da campioni di sangue del cordone ombelicale umano. Studi precedenti hanno dimostrato che i topi anziani a cui è stato iniettato plasma di topo giovane hanno recuperato la funzione di memoria spaziale e la somministrazione sistemica di plasma sanguigno del cordone ombelicale ha migliorato la cognizione dipendente dall'ippocampo nei topi anziani [5, 8]. L'iniezione di plasma, che è privo di componenti cellulari, ha ridotto al minimo il rischio di rigetto immunitario derivante dalla mancata corrispondenza delle specie. I topi anziani (età iniziale, 18 mesi) sono stati randomizzati e hanno ricevuto plasma (un gruppo di trattamento) o tampone salino (un gruppo fittizio) tramite iniezione di coda (130 µ l; vedere la figura S1 per i dettagli). Come controllo positivo sono stati utilizzati topi giovani (di 3 mesi). Il plasma derivato dal sangue del cordone ombelicale non è stato raggruppato e ogni topo è stato ripetutamente infuso con plasma dello stesso donatore (Fig. S1). Dopo una 4-settimana di trattamento, i topi sono stati sottoposti a un test comportamentale (ad es. rotarod) e il sangue è stato prelevato per le analisi.

image

Figura 1. Disegno sperimentale. Il plasma del sangue del cordone ombelicale è stato somministrato ai gruppi giovani ({1}}di un mese), anziani (20- e 23-di un mese) e anziani trattati con plasma (20- e 23-mese). I tre gruppi sono stati sottoposti a 2-test Rotarod di prova per misurare la coordinazione motoria e l'apprendimento. La profilazione dei metaboliti non mirati è stata eseguita sul sangue dei tre gruppi e della maggior parteanti età-il percorso rilevante è stato determinato attraverso un approccio bioinformatico. Il biosensore è stato sviluppato per rilevare il metabolita più importante del percorso.

image

Figura 2. Determinazione dei biomarcatori del metabolita associati al trattamento con plasma del sangue del cordone ombelicale umano. (A) Profilo globale della perturbazione del metabolita. Le righe corrispondono alle caratteristiche (una combinazione unica di valore m/z e tempo di ritenzione) da LC/MS e le colonne ai campioni. Le righe sono raggruppate gerarchicamente. (B) Grafico del punteggio di PCA per la riduzione dimensionale. I campioni sono stati tracciati rispetto ai componenti principali (PC) 1 e 2. I valori tra parentesi delle legende degli assi sono proporzioni di varianza spiegate da tali componenti. PC1 molto probabilmente spiega gli effetti anti-invecchiamento, dato che il gruppo trattato con plasma era molto più vicino al gruppo giovane che al gruppo sham. (C) Analisi dell'arricchimento del percorso. I metaboliti sono stati identificati confrontando i valori m/z misurati con le informazioni sulla massa molecolare. Ogni cerchio rappresenta un percorso specifico trovato. Per un determinato percorso, la posizione x o la dimensione del cerchio corrisponde alla centralità della relativa tra (una misura dell'impatto del percorso) dei metaboliti e la posizione o il colore y (valori p inferiori per il rosso e più alti per il blu) nella misura in cui quali metaboliti sono sovrarappresentati. I percorsi dominanti hanno valori xey più alti. Di conseguenza, il metabolismo dell'acido arachidonico (AA) è stato identificato come la via più probabile per spiegare ileffetti antietàdel plasma sanguigno del cordone ombelicale.

1635996154(1)

Analisi metaboliche su campioni di sangue di topo

Per prima cosa abbiamo eseguito un profilo imparziale del metabolita di piccole molecole nel plasma del topo. I campioni di sangue di tutti e tre i gruppi di topi sono stati sottoposti a cromatografia liquida e analisi di spettrometria di massa (LC/MS). Abbiamo elaborato i dati m/z mediante MAIT (metabolite automatic identifier toolkit) e identificato caratteristiche statisticamente significative tramite ANOVA (8572 combinazioni uniche di m/z e tempo di ritenzione) (Fig. 2a). L'analisi di clustering gerarchico (HCA) dei metaboliti ha rivelato due modelli chiave: i) i profili dei metaboliti erano nettamente diversi tra topi anziani (non trattati) e giovani; e ii) il profilo dei topi anziani trattati con plasma era più vicino a quello dei topi giovani.

L'analisi delle componenti principali (PCA) ha rivelato strutture intrinseche dei dati metabolomici (Fig. 2b). Circa il 50 per cento delle variazioni totali erano spiegabili dalla prima (PC1) e dalla seconda componente principale (PC2). Tutte e tre le coorti (cioè giovani, trattati con plasma e gruppi fittizi) si sono stabilite in posizioni discrete, indicando che sono state identificate caratteristiche biologicamente rilevanti per differenziare le classi di gruppo. È interessante notare che il gruppo di anziani trattato con plasma si è allontanato dalla finzione verso il gruppo giovane. Per quantificare la separazione dei gruppi, abbiamo calcolato il clustering gerarchico sulle due componenti principali. Nel dendrogramma, i gruppi giovani e trattati con plasma erano raggruppati a un livello di dissomiglianza inferiore (o un livello di somiglianza più alto, 1120,9) rispetto al gruppo non trattato (3162,5) (Fig. S2). Questi risultati indicano che le caratteristiche selezionate (variabili o righe in Fig. 2a) possono essere utilizzate per dedurre il biomarcatore del metabolita rilevante per l'invecchiamento eanti età. Abbiamo annotato le caratteristiche con metaboliti noti utilizzando un database di pubblico dominio [9].

Abbiamo ulteriormente valutato le funzioni e l'interconnettività dei metaboliti identificati, applicando la mappatura KEGG (Kyoto Encyclopedia of Genes and Genomes) [10]. Per un dato percorso, abbiamo misurato i) la sovrarappresentazione di un metabolita candidato e ii) la sua importanza (cioè, centralità tra i due) [11] come nodo intermedio chiave tra coppie di altri metaboliti (vedi Metodi per i dettagli). Abbiamo scoperto che il metabolismo dell'acido arachidonico (AA) era il percorso più sovrarappresentato (il valore y più alto in Fig. 2c) e i metaboliti in quel percorso tendevano a localizzarsi nei percorsi di comunicazione (valori x più alti in Fig. 2c) e governare il flusso di informazioni. Tra i molti metaboliti nel metabolismo dell'AA, abbiamo selezionato l'AA stesso come biomarcatore; come ingresso iniziale nel percorso, l'AA da solo può essere un rappresentante di altri metaboliti perturbati.

Sensore magnetoelettrochimico competitivo (cMES) per il rilevamento di AA nel plasma

Successivamente abbiamo deciso di far avanzare un sistema di analisi rapido e in loco per il rilevamento di AA. Abbiamo scelto di utilizzare la tecnologia di rilevamento magneto-elettrochimico [12-17]. Combina l'arricchimento e il rilevamento del bersaglio in un'unica piattaforma: le sfere magnetiche (MB) vengono utilizzate per catturare ed etichettare i bersagli molecolari e i bersagli legati alle sfere vengono rilevati tramite il rilevamento elettrochimico. Questo approccio ha molti vantaggi pratici: i) i campioni nativi (plasma o sangue) possono essere utilizzati direttamente senza la necessità di purificazione del campione; ii) il saggio raggiunge un'elevata sensibilità di rilevamento attraverso l'arricchimento magnetico e l'amplificazione enzimatica del segnale; iii) in base allo schema elettrico di rilevamento, i sensori possono essere facilmente miniaturizzati come un dispositivo portatile (Fig. 3a).

Il rilevamento dell'AA attraverso il rilevamento magnetoelettrochimico, tuttavia, ha rappresentato una sfida tecnica; poiché l'AA è una piccola molecola (~ 304,5 Da), i test immunologici che utilizzano una coppia di anticorpi AA erano difficili da applicare. Abbiamo quindi esplorato un formato di analisi competitivo (cMES; sensore magneto-elettrochimico competitivo) che richiedeva solo un singolo anticorpo AA (Fig. 3b). Per l'acquisizione del bersaglio, abbiamo rivestito MB con anticorpi AA (MBAb). Abbiamo anche preparato un agente concorrente (AA-HRP) coniugando AA con un enzima ossidante (perossidasi di rafano, HRP). Nello specifico, abbiamo usato una forma aptenica; AA coniugato su albumina sierica bovina (BSA) e ulteriormente coniugato HRP al vettore BSA (Fig. S3). Per il test cMES, i campioni di sangue sono stati miscelati con MBAb e AA-HRP. La quantità di AA-HRP è stata sufficiente per saturare i siti di legame AA in MBAb (Metodi). Ciò comporterebbe un carico differenziale di HRP sui MB, a seconda delle quantità di AA endogene nei campioni. L'aggiunta sequenziale di un mediatore di elettroni cromogenico (3,3',5,5'-tetrametilbenzidina, TMB) ha generato una corrente elettrica che è stata letta da un elettrodo planare. Il tempo di reazione per la cattura di AA e l'incubazione TMB è stato ottimizzato per massimizzare il livello del segnale (Fig. S4).

image

Figura 3. Sensore magneto-elettrochimico competitivo (cMES) per il test AA. (A) Schema del dispositivo. Il dispositivo cMES ha un ingombro ridotto e offre

operazioni in loco. (B) Abbiamo ideato un saggio elettrochimico competitivo per il rilevamento di AA. Perline magnetiche (MBAb) sono state coniugate con anticorpi contro AA.

I campioni di controllo contenevano solo AA-HRP e sono stati miscelati con sfere magnetiche. I campioni del test sono stati miscelati con sfere magnetiche e AA-HRP. (C) Correnti elettriche

misurata dal lettore portatile cMES. Nel test cMES, l'intensità della corrente diminuisce all'aumentare della concentrazione di AA [AA]. Il segnale dal controllo

campione impostare la linea di base per [AA]=0 ng/mL. La differenza di corrente (∆I) tra il controllo ei campioni di plasma mirati è stata utilizzata come metrica analitica. (D)

Le quantità note di AA sono state aggiunte nel siero e misurate dal cMES. Il limite di rilevamento era di ~ 126 ng/mL. (E) sono stati confrontati cMES ed ELISA

concordanza. I risultati di entrambe le modalità hanno mostrato un buon accordo (R2=0.959). I dati vengono visualizzati come media ± SEM da misurazioni triplicate.

image

Figura 4. Misurazioni di AA in campioni di plasma. (A) Analisi dell'andamento temporale del livello di AA del topo dopo l'iniezione di plasma. Abbiamo iniettato 13{{10}} μL di plasma (concentrazione di AA=7.2 μg/mL) nei topi (n=6) e raccolto sangue di topo dopo 3, 7 e 14 giorni. Sono stati quindi monitorati i livelli di AA nel sangue di topi. I livelli di AA sono aumentati significativamente al giorno 3 e sono tornati al livello normale dopo 7 giorni. *p < 0.05;="" **p="">< 0.01;="" ***p="">< 0.001.="" (b)="" sono="" stati="" analizzati="" campioni="" di="" plasma="" di="" topo.="" nel="" gruppo="" di="" controllo="" (n="5)," i="" topi="" giovani="" (età,="" 5="" e="" 8="" mesi)="" avevano="" livelli="" di="" aa="" più="" elevati="" rispetto="" ai="" topi="" vecchi="" trattati="" con="" sham="" (età,="" 20="" e="" 23="" mesi;="" n="8)." per="" il="" gruppo="" trattato="" con="" plasma="" (n="5)," è="" stato="" osservato="" un="" aumento="" sostenuto="" di="" aa.="" *p="">< 0,05;="" **p="">< 0,01;="" ***p="">< 0,001.="" (c)="" i="" campioni="" di="" plasma="" delle="" stesse="" coorti="" di="" (b)="" sono="" stati="" analizzati="" mediante="" spettrometria="" di="" massa.="" i="" livelli="" di="" aa="" hanno="" mostrato="" una="" tendenza="" simile="" misurata="" da="" cmes.="" *p="">< 0,05;="" **p="">< 0,01;="" ***p="">< 0,001.="" i="" dati="" vengono="" visualizzati="" come="" media="" ±="">

Come risultato del test competitivo, l'entità della corrente elettrica è diminuita con concentrazioni plasmatiche di AA più elevate ([AA]). Abbiamo quindi preparato un campione di controllo incubando MBAb solo con AA-HRP. Il campione di controllo è stato utilizzato per impostare la linea di base superiore (cioè, [AA]=0 ng/mL) per il calcolo delle differenze di segnale; sono state misurate le correnti elettriche dal controllo e dal campione di plasma e la differenza netta |∆I |=|Icontrol - Iplasma|è stato ottenuto (Fig. 3c). Tale

le misurazioni differenziali hanno anche compensato il segnale di fondo comune.

L'esperimento di titolazione (Fig. 3d) utilizzando campioni addizionati con quantità variabili di AA ha rivelato il limite di rilevamento (LOD) di ~ 125,9 ng/mL. Il LOD del test era ~300- volte inferiore alla tipica concentrazione di AA di (38 µg/ml) nel plasma di topi giovani (5 mesi, n=2). Sulla base di questi risultati, abbiamo diluito i campioni di plasma iniziali (100- volte) aggiungendo una soluzione tampone (vedi Metodi). Il segnale del legame non specifico era vicino a un livello di fondo intrinseco (~ 43 nA), beneficiando potenzialmente dell'alto fattore di diluizione. Abbiamo anche confermato che i risultati del test corrispondevano a quelli dell'ELISA convenzionale (R2=0.961, Fig. 3e). Il test cMES, tuttavia, è stato più veloce (1 ora) di ELISA (4 ore), principalmente a causa della cinetica di legame veloce; nel cMES, i MB catturano AA nell'intero volume del campione (3-diffusione dimensionale), mentre l'acquisizione AA si basa sulla 1-diffusione dimensionale nell'ELISA su piastra.

Monitoraggio di AA nei topi trattati con plasma

Abbiamo applicato cMES per analizzare i livelli di AA nei topi dopo un singolo trattamento al plasma. Poiché l'AA è naturalmente presente nel sangue del cordone ombelicale umano, l'iniezione di plasma aumenterebbe in modo additivo i livelli di AA del topo. La concentrazione media di AA da sei diversi plasma sanguigno cordonale umano era 7,2 ± 0,5 µg/mL (media ± SEM). Abbiamo iniettato 130 µL di plasma sanguigno del cordone ombelicale umano ai topi (n=6) e monitorato i loro livelli di AA (Fig. 4a). L'iniezione di plasma ha immediatamente aumentato i livelli di AA nel sangue (giorno 3; p <0,01, rispetto="" a="" tutti="" gli="" altri="" punti="" temporali),="" ma="" l'effetto="" è="" stato="" temporaneo;="" i="" livelli="" di="" aa="" sono="" tornati="" alla="" normalità="" 7="" giorni="" dopo="" il="" trattamento="" (p="0.34," rispetto="" al="" punto="" temporale="" prima="" dell'iniezione="" di="">

Successivamente monitoriamo i livelli plasmatici di AA dopo il programma di trattamento completo (Fig. S1). Sono state utilizzate tre diverse coorti di topi: un gruppo trattato con plasma (n=8) e uno simulato (n=8) di età (20-23 mesi) e un gruppo di controllo giovane (<8 months="" old,="" n="5)." we="" used="" 0.5="" µl="" of="" mouse="" plasma="" for="" each="" measurement.="" the="" sham="" group="" showed="" lower="" aa="" level="" compared="" to="" the="" young="" group="" (p="0.003," fig.="" 4b).="" the="" plasma="" treated="" group,="" however,="" showed="" increased="" aa="" levels="" even="" after="" 1="" month="" after="" the="" treatment.="" the="" effect="" was="" sustained="" up="" to="" 4="" months="" post="" treatment;="" the="" plasma-treated="" group="" had="" higher="" aa="" level="" than="" the="" sham="" group="" (p="0.0003)." we="" also="" analyzed="" aliquots="" of="" samples="" via="" lc/ms="" (fig.="" 4c).="" the="" results="" from="" both="" assays="" were="" concordant,="" corroborating="" aa's="" value="" as="" a="">

Trattamento al plasma che porta al miglioramento cognitivo e comportamentale nei topi anziani

Abbiamo ulteriormente valutato i fenotipi comportamentali delle coorti animali, valutando in particolare il loro apprendimento motorio e le funzioni di memoria. Abbiamo eseguito {{0}}prove rotarod test a 1 e 4 mesi dopo il trattamento con plasma o sham (Fig. 5a); la latenza (tempo di esecuzione) di un topo prima di cadere su un'asta rotante è stata utilizzata per valutare le prestazioni motorie dell'animale. A 1 mese dal trattamento (20-mese di età), la latenza sia del gruppo sham che del gruppo trattato con plasma era significativamente inferiore (p < 0,0001)="" rispetto="" a="" quella="" dei="" giovani="" ({10}}mese="" )="" (fig.="" 5b).="" il="" gruppo="" trattato="" con="" plasma,="" invece,="" ha="" mostrato="" un="" graduale="" miglioramento="" dell'apprendimento="" motorio="" e="" della="" memoria,="" mentre="" la="" stessa="" facoltà="" è="" diminuita="" nel="" gruppo="" sham.="" i="" cambiamenti="" nei="" livelli="" di="" aa="" hanno="" comportato="" cambiamenti="" comportamentali,="" che="" potrebbero="" fungere="" da="" indicatore="" precoce="">anti etàeffetto del trattamento (Fig. 5c).

Le analisi del tessuto cerebrale (Figg. 5d, 5e) hanno mostrato che i topi anziani (il gruppo fittizio) avevano un'area più piccola di cellule DCX-positive nella zona subventricolare rispetto ai topi giovani. Al contrario, l'area delle cellule DCX-positive è aumentata nell'animale trattato con plasma ed è rimasta invariata (p=0.04) indicando che il plasma sanguigno del cordone ombelicale iniettato stimolava la neurogenesi del vecchio cervello. I risultati suggeriscono il potenziale beneficio del trattamento al plasma sulla neurogenesi sostenuta che ha portato a una migliore funzione motoria nel gruppo trattato.

Discussione

I progressi nelle terapie di ringiovanimento aumentano contemporaneamente la necessità di una misura oggettiva e quantitativa per leggere l'efficacia del trattamento. Abbiamo quindi progettato il nostro studio per identificare i biomarcatori molecolari che possono spiegare al meglio le caratteristiche fenotipiche dell'invecchiamento eanti etàtrattamento. I nostri esperimenti sugli animali hanno portato alle seguenti osservazioni: i) i profili metabolici di coorti di topi giovani e adulti sono evidentemente differenti; e ii) l'iniezione di plasma cordonale umano in topi anziani cambia i loro schemi metabolici più vicini a quelli dei topi giovani. È interessante notare che abbiamo trovato l'acido arachidonico (AA) come il biomarcatore surrogato più efficace peranti etàtrattamento; Il metabolismo dell'AA era altamente non regolato sia nei topi giovani che in quelli trattati con plasma, e si è scoperto che giocava un ruolo chiave nell'interazione con altre vie metaboliche come il metabolismo dell'acido linoleico [10, 18].

Abbiamo ulteriormente sviluppato un sistema di sensori veloce e portatile (cMES) per facilitare il rilevamento di AA nella ricerca di routine e nelle impostazioni cliniche. Abbiamo specificamente integrato uno schema di analisi competitivo con arricchimento immunomagnetico nel tentativo di rilevare piccoli bersagli molecolari (cioè metaboliti) direttamente dai campioni di plasma. Questa combinazione porta i seguenti vantaggi. (i) Il test beneficia di una cinetica di legame veloce, poiché le sfere magnetiche catturano l'AA nell'intero volume del campione (3-diffusione dimensionale). (ii) I processi di analisi (ad es. fasi di lavaggio) sono semplificati con magneti esterni utilizzati per la raccolta delle perline. (iii) Concentrando magneticamente le sfere legate all'AA vicino all'elettrodo di rilevamento, il segnale analitico complessivo può essere migliorato (~72 percento) [12]. In effetti, abbiamo dimostrato che il test cMES utilizza<1 µl="" of="" plasma="" with="" the="" total="" assay="" time="" within="" 1.5="" hour.="" both="" cmes="" and="" mass="" spectrometry="" consistently="" showed="" that="" plasma="" aa="" levels="" decrease="" with="" aging,="" but="" that="" they="" reversely="" increase="" with="" cord-plasma="" treatment.="" importantly,="" increases="" in="" aa="" levels="" could="" be="" an="" early="" indicator="" of="" improved="" cognitive="" functions="" in="" treated="" animals.="" these="" results="" highlight="" the="" utility="" of="" aa-cmes;="" with="" minimally="" invasive="" blood="" draw,="" individual="" patients="" can="" be="" monitored="" in="" a="" serial="" fashion="" to="" better="" assess="" treatment="">


image

Figura 5. Saggi comportamentali e molecolari. (A) 2-prova I test Rotarod sono stati condotti 1 e 4 mesi dopo l'iniezione di plasma. (B) Il gruppo trattato con plasma

ha mostrato un progressivo miglioramento della coordinazione motoria; la prestazione è stata alla fine vicina a quella del gruppo dei giovani (seconda prova a 3 mesi). Il tempo di esecuzione del gruppo fittizio è diminuito con l'invecchiamento. *p < 0.05;="" **p="">< 0.01.="" (c)="" per="" il="" gruppo="" trattato="" con="" plasma,="" l'aumento="" dei="" livelli="" di="" aa="" ha="" preceduto="" il="" miglioramento="" della="" funzione="" motoria.="" *p="">< 0.05;="" **p="">< 0,01;="" ***p="">< 0,001.="" (d)="" le="" cellule="" cerebrali="" nella="" zona="" subventricolare="" sono="" state="" immunocolorate="" per="" un="" marcatore="" di="" neurogenesi,="" doublecortin="">

La barra della scala è 50 µm. Si noti che il gruppo sham aveva un'area significativamente più piccola di cellule DCX-positive nella zona subventricolare rispetto ai topi giovani, mentre l'area è aumentata nell'animale trattato con plasma ed è rimasta invariata. (E) È stata misurata l'area delle cellule DCX-positive nell'immagine (D). *p < 0.05;="" ***p=""><>

È stato dimostrato che l'AA promuove la crescita muscolare e lo sviluppo del cervello [19, 20]. Anche altri rapporti hanno evidenziato i potenziali vantaggi dell'AA inanti età[21, 22]. Il presente studio è in linea con questi risultati, ma il suo scopo era limitato a stabilire una relazione correlativa tra i livelli di AA eanti etàfenotipi. Il monitoraggio seriale di AA, tuttavia, ha indicato che gli aumenti di AA nei topi trattati con plasma erano probabilmente da fonti endogene, non da plasma trasfuso. Inoltre, sostenutoanti etàgli effetti sono stati osservati nei topi riceventi anche 4 mesi dopo la fine del trattamento con plasma. Migliorate le funzioni di apprendimento motorio e di memoria; e il numero di cellule precursori neuronali è aumentato nel cervello. Queste osservazioni suggeriscono fortemente cambiamenti fisiologici nei topi trattati con plasma; il meccanismo esatto deve ancora essere chiarito.

Diverse altre limitazioni di questo studio dovrebbero essere affrontate nella ricerca futura. In primo luogo, il test cMES deve essere perfezionato per una maggiore precisione. In particolare, con la mancanza di campioni veri negativi (cioè campioni di sangue senza AA endogeni), era difficile tenere conto dei segnali di legame non specifico. È plausibile che l'effetto delle matrici ematiche possa essere trascurabile poiché abbiamo diluito i campioni di 100-volte. Tale ipotesi, tuttavia, deve essere convalidata utilizzando campioni di plasma eliminati con AA che potrebbero essere preparati da un modello murino carente di AA [23] o mediante immunodeplezione di AA. In secondo luogo, ci siamo concentrati sul rilevamento di un singolo metabolita nel metabolismo dell'AA per semplicità, ma questo approccio può ignorare il contesto biologico come le interazioni tra i metaboliti in un determinato percorso. Includere un pannello di metaboliti catturerebbe meglio le perturbazioni metaboliche e aumenterebbe anche l'accuratezza diagnostica. cMES può essere facilmente ridimensionato per rilevare diversi marcatori consumando piccole quantità di campione. In terzo luogo, sarebbe difficile interpolare i risultati attuali con gli esseri umani. Sebbene i topi e gli esseri umani condividano percorsi metabolici simili, i topi hanno un tasso metabolico 7- volte più alto rispetto agli esseri umani [24]. Sono necessari studi sull'uomo per determinare le dosi plasmatiche ottimali per l'infusione e per stabilire i valori di riferimento per i biomarcatori; informato da studi sugli animali, stiamo pianificando tali studi sull'uomo. Questi sforzi accelereranno lo sviluppo dianti etàterapie, migliorando la qualità della vita individuale e riducendo gli oneri sociali.

1635996141(1)

Metodi

Design sperimentale

Il plasma è stato separato dal sangue del cordone ombelicale umano raccolto al momento del parto. Il plasma del sangue del cordone ombelicale è stato somministrato mediante infusione endovenosa a topi anziani (di 18-mesi di età) e controllo fittizio (di 18-mesi di età) e topi giovani (di 3-mesi di età come positivi controllo) è stato iniettato con soluzione fisiologica. A 1 e 4 mesi dopo il trapianto, 2-sono stati condotti test rotarod di prova per valutare la coordinazione motoria e la memoria a lungo termine (Fig. S1). Il profilo del metabolita non mirato è stato eseguito sul sangue dei tre gruppi e l'analisi bioinformatica ha determinato ilanti etàvia rilevante (metabolismo dell'acido arachidonico). Il biosensore è stato sviluppato per rilevare l'acido arachidonico circolante in modo semplice ed efficiente.

Preparazione del campione di sangue cordonale

Il sangue del cordone ombelicale è stato raccolto nell'ambito dell'Institutional Review Board del CHA General Hospital (Seoul, Corea, IRB n. CHAMC-2015- 08-130-009). Il sangue del cordone ombelicale umano è stato donato da 4 donatori e trattato con citrato-fasfato-destrosio con anticoagulante adenina (CPDA-1). Il plasma sanguigno del cordone ombelicale è stato isolato mediante centrifugazione a 2,{6}} g per 15 minuti a temperatura ambiente. I campioni di plasma isolati sono stati conservati a -80 gradi e utilizzati con un unico ciclo di congelamento-scongelamento a temperatura ambiente.

Esperimenti sugli animali

I protocolli sugli animali sono stati approvati dal Comitato istituzionale per la cura e l'uso degli animali dell'Università CHA (IACUC). Abbiamo utilizzato 18-topi C57BL/6 femmine di un mese per valutare le perturbazioni metaboliche e i fenotipi comportamentali correlati all'invecchiamento eanti età. I controlli positivi erano topi C57BL/6 femmine di 3-mesi di età. Tutti i topi sono stati allevati a temperatura ambiente in un ciclo luce-buio standard di 12 ore. Per i topi adulti, il plasma del sangue del cordone ombelicale o la soluzione salina (130 µl) sono stati iniettati per via endovenosa 12 volte per 4 settimane. Il plasma del sangue del cordone ombelicale umano isolato non è stato riunito e un dato animale ha ricevuto plasma del sangue del cordone ombelicale dallo stesso donatore. Il numero di animali utilizzati in ciascun esperimento è descritto nelle sezioni del metodo corrispondenti. Il plasma è stato raccolto mediante centrifugazione (3,{10}} g, 15 minuti a temperatura ambiente).

Acquisizione dei metaboliti e analisi dei dati

Per la profilazione dei metaboliti ematici, il sangue è stato raccolto dai topi mediante puntura cardiaca nei punti temporali designati: il gruppo giovane (3-di un mese, n=10), il gruppo fittizio ({{ 4}}mese, n=10; 23-mese, n=12), il gruppo trattato con plasma (20-mese, n {{13 }}; 23-mese, n=5). I campioni di sangue sono stati analizzati utilizzando un sistema di cromatografia liquida-spettrometria di massa (LC-MS) (Agilent). Abbiamo convertito i file LC/MS in un formato mzXML standard (ProteoWizard) [25] e quindi li abbiamo elaborati utilizzando MAIT (metabolite automatic identifier toolkit) [26] per il rilevamento delle caratteristiche, l'analisi statistica e l'identificazione dei metaboliti. Le caratteristiche statisticamente significative (ossia, metaboliti ionizzati e/o frammentati) sono state identificate tramite l'analisi della varianza (ANOVA). Queste caratteristiche sono state abbinate a tutti i possibili metaboliti presunti nel database del metaboloma [9] in base al rapporto massa/carica dello ione spettrale di massa (tolleranza m/z di 0.005). Abbiamo caratterizzato le alterazioni globali dei metaboliti tramite l'analisi del clustering gerarchico e le strutture intrinseche dei dati metabolomici tramite l'analisi dei componenti principali (PCA). Due o tre repliche tecniche (assicurando che la variazione tecnica sia molto più piccola della variazione biologica) per topo sono state incluse nell'apprendimento non supervisionato come PCA e clustering gerarchico. Il clustering gerarchico sui componenti principali (HCPC) è stato eseguito da FactoMineR, un pacchetto R [27]. Per un'analisi funzionale, le vie metaboliche più probabili da perturbare dall'invecchiamento e dal trattamento plasmatico sono state determinate tramite l'analisi della via KEGG (MetaboAnalyst 3.0) [28]. La distribuzione ipergeometrica è stata utilizzata per misurare la sovrarappresentazione dei metaboliti abbinati in percorsi KEGG specifici.

Preparazione di sfere immunomagnetiche

Perline magnetiche (5 mg) rivestite con gruppi epossidici (Dynabeads M-270 Epoxy, Invitrogen) sono state sospese in 100 µL di soluzione 0,1 M di fosfato di sodio. Cento microgrammi di anticorpo contro l'acido arachidonico (Biomatik) sono stati aggiunti e miscelati accuratamente. Sono stati aggiunti cento microlitri di soluzione di solfato di ammonio 3 M e la miscela è stata incubata a temperatura ambiente per 2 ore e quindi ulteriormente incubata a 4 gradi per una notte con rotazione lenta di inclinazione. La reazione di coniugazione è stata condotta a pH=7.4. Questi processi inducono la formazione di legami covalenti tra gruppi epossidici (perline) e gruppi amminici (anticorpi), che abbiamo precedentemente confermato sottoponendo coniugati anticorpo-perline a sfide di pH [29]. In media 2,4 × 104 anticorpi sono stati immobilizzati per perlina. Le sfere magnetiche coniugate con anticorpi sono state separate con un magnete permanente, lavate due volte con una soluzione di PBS e risospese in 200 µl di PBS con l'1% di BSA. Le perle sono state conservate a 4 gradi fino a un mese.

Coniugazione HRP con acido arachidonico

HRP è stato quindi coniugato con BSA tramite chimica di amminazione riduttiva. In particolare, 100 µg di AA coniugato con BSA (RPU51089, Biomatik) è stato sciolto in 0,5 mL di tampone carbonato-biocarbonato 0,2 M (pH 9,4), aggiunto a un milligrammo di EZ-link liofilizzato Plus attivato perossidasi (Thermo Scientific) e incubato per 1 ora a temperatura ambiente. Successivamente, sono stati aggiunti 10 µL di cianoboroidruro di sodio (Thermo Scientific) e la miscela è stata incubata per 15 minuti a temperatura ambiente. Infine, sono stati aggiunti 20 µL di Quenching buffer (Thermo Scientific), seguiti da 15 minuti di incubazione a temperatura ambiente. L'elettroforesi su gel e l'analisi della banda proteica hanno confermato la coniugazione HPR con BSA-AA (Fig. S3a). Gli AA coniugati con HRP sono stati raccolti e concentrati con un filtro centrifugo Amicon Ultra 100K (Millipore). La perossidasi e la BSA-AA rimanenti sono state lavate con PBS per quattro volte.

Rilevazione elettrochimica di AA in campioni di plasma

Per il rilevamento elettrochimico di AA, il sangue è stato raccolto dai giovani (n {0}}), sham (n=8) e dai gruppi trattati con plasma (n=5 per 1 mese e n=5 per 3 mesi). Campioni di plasma di topo (0.5 µL) sono stati diluiti in 50 µL di BSA all'1% in PBS (×{11}}fold dilution) e miscelati con una soluzione di microsfere immunomagnetiche (50 µL) e una soluzione di AA coniugata con HRP (50 µl). La quantità di AA-HRP era abbastanza grande da saturare i siti di legame nelle sfere magnetiche. Abbiamo utilizzato circa 8,4 × 107 perline per test, il che ha reso disponibili 2,0 × 1012 siti di legame AA. La quantità di AA-HRP era ~ 1,7 × 1013; il rapporto tra AA-HRP e siti di legame era di circa 8:1. La miscela è stata incubata a temperatura ambiente per 1 ora con rotazione di inclinazione lenta. La microsfera di controllo è stata preparata miscelando l'1% di BSA in PBS (50 µl) con una soluzione di microsfere immunomagnetiche (50 µl) e una soluzione di AA coniugata con HRP (50 µl). Tutti i granuli reagiti sono stati separati con un magnete permanente e lavati due volte con 80 µl di PBS (1% BSA). Infine, le perline sono state risospese in 7 µl di PBS. La soluzione di perline preparata e 20 µ l di soluzione TMB (Biomatik) sono stati caricati sopra l'elettrodo. Dopo 6 minuti è stata avviata la misurazione della cronoamperometria. Abbiamo utilizzato un sensore elettrochimico miniaturizzato (un prototipo di sistema sviluppato da AcurrHealth Inc.). I livelli attuali nell'intervallo di 40-45 s sono stati mediati. Abbiamo utilizzato il fattore di conversione (×100) per riportare le concentrazioni originali stimate di AA nel plasma.

Saggio di immunoassorbimento enzimatico (ELISA)

Gli esperimenti ELISA sono stati eseguiti utilizzando il kit ELISA di acido arachidonico (AA) di topo (Biomatik) secondo le linee guida di produzione. AA diluiti in serie sono stati aggiunti in ciascun pozzetto e incubati con AA coniugato con HRP a 37 gradi per 40 minuti. Dopo il lavaggio con tampone di lavaggio per quattro volte, è stata aggiunta la soluzione di TMB e incubata per 20 minuti. Lo sviluppo del colore è stato interrotto aggiungendo una soluzione di arresto. L'assorbanza è stata letta a 450 nm utilizzando un lettore di micropiastre (Tecan).

Prova Rotarod

Abbiamo modificato il test Rotarod di Kong et al. [30] per valutare la coordinazione locomotoria. Il rotarod con un'asta di diametro di 3-cm è iniziato a 4 giri al minuto e ha accelerato di 4 giri al minuto ogni 30 secondi per 5 minuti. I topi sono stati posti sull'asta ed è stato misurato il tempo impiegato dai topi per cadere dall'asta. Ogni topo ha ricevuto 3 prove al giorno e i tempi di esecuzione di ogni giorno sono stati calcolati come media dei tempi di allenamento. Il primo test rotarod è stato condotto a 1-mese dopo il trattamento con plasma: il gruppo giovane (n=29), il gruppo sham (n=17), il gruppo trattato con plasma (n {{ 11}}). Una sessione di riqualificazione è stata avviata a 4-mesi dopo il trattamento con plasma. Per evitare il sovrallenamento, la riqualificazione è stata condotta per 2 giorni. L'altra procedura era la stessa della prima sessione.

Imaging del tessuto cerebrale

A 1 mese (n=4) e 4 mesi (n=3) dopo l'iniezione di plasma sanguigno del cordone ombelicale o iniezione di soluzione fisiologica, gli animali sono stati sottoposti a eutanasia e quindi perfusi con paraformaldeide al 4% (PFA) e PBS attraverso il ventricolo sinistro. I gruppi giovani (n=5) e fittizi (n=4) sono stati usati come controlli. I loro cervelli erano

estratto e crioprotetto. Ogni cervello è stato sezionato su un criotomo con uno spessore di 30 μm. Per

eseguire l'immunoistochimica, il legame non specifico è stato bloccato con il 5% di siero di capra normale in 0,3% Triton X-100 per 40 min. L'anticorpo primario contro la doppiacortina (DCX; 1:400, Segnalazione cellulare, #4604S) è stato applicato durante la notte a 4 gradi, quindi è stato utilizzato PBS per il lavaggio [31]. Per il rilevamento di DCX è stato utilizzato l'anticorpo secondario Alexa Fluor 488 (1:2000, Invitrogen, #A11008). Le immagini sono state riprese utilizzando un microscopio a fluorescenza (Nikon Eclipse 80i) e analizzate utilizzando l'immagine J [32].

analisi statistica

L'analisi statistica è stata eseguita utilizzando le funzioni di base R e lme4, un pacchetto R per entrambi Linear

Modelli a effetti misti o modello lineare generalizzato

(GLM) seguito da un test post-hoc LSD [33]. I dati sono presentati come media ± errore standard e un valore p < 0.05="" è="" stato="" considerato="">

Materiale supplementare

Cifre supplementari.

http://www.thno.org/v09p0001s1.pdf

Ringraziamenti

Ringraziamo AccureHealth Inc. per aver fornito il sensore elettrochimico miniaturizzato. Questo studio è stato sostenuto in parte dalla sovvenzione dell'Institute for Information and Communications Technology Promotion (IITP) finanziata dal governo coreano (MSIT) (2017M3A9B4025699).

Interessi conflittuali

Gli autori hanno dichiarato che non esiste alcun interesse concorrente.